LST14 thermostove: all safety you deserve
For the smoke discharge, a high-tech pressostat.
A mechanic vacumstat checks that all conditions are applied. In case of obstructions, the thermostove will shut down itself. The same thing happens if accidentally the door is opened during the functioning. A sensor checks the gas temperature.
For the electrical safety,
2 fuses (2,5 A - 250 V). In the case of electrical surcharges (a lightning for example) the thermostove is protected by 2 fuses.
Two sensors are connected with the pellet tank temperature and the circulation pump. In the case that the temperature in the pellet tank is abnormal or the water temperature is too high or the circulation pump breaks down, the safety sensor will generate an alarm and shut down the stove.
|
| LST14CB-LST14CS-LST14CK-LST14AB-LST14AS-LST14AK |
| Forced ventilation |
- |
Without |
With |
| Unit dimensions (WxHxD) |
mm |
600x1140x610 |
| Net Weight |
kg |
120 |
120 |
| Air inlet tube Ø |
mm |
60 |
60 |
| Smoke outlet tube Ø |
mm |
80 |
80 |
| Heatable area* |
mq |
180 |
180 |
| Autonomy (min-max) |
hours |
10,4-31 |
10,4-31 |
| Nominal thermal output |
kW |
4,0 - 12,0 |
4,0 - 12,0 |
| Water heat output |
kW |
11,5 |
9 |
| Space heat output |
kW |
0,5 |
3,1 |
| Fuel |
- |
pellet |
pellet |
| Pellet fuel consumption (min-max) |
kg/hour |
0,3-3,3 |
0,3-3,3 |
| Efficiency |
% |
87 |
90 |
| Tank capacity |
kg |
30 |
30 |
| Power input |
W |
90-380 |
90-380 |
| Finish |
- |
Majolica/Painted Steel |
| Power supply |
V-Hz |
230-50 |
230-50 |
| Number of phases |
- |
1 |
1 |
| Sanitary water kit |
- |
Optional |
Optional |
| Majolica available colours |
- |
Sand-Red-Black |
| Painted steel available colours |
- |
Sand-Red-Black |
|
6. Hydrometer or pressure trasductor
7. Pressostat
8. Pellet tank sensor
9. Tangential fan
10. Air outlet
11. Water inlet
12. Water outlet
13. Air inlet
14. Ambient thermostat
15. Rearming button pellet tank probe
16. Rearming button water circulation
17. Ambient thermostat
*The heatable area can vary depending on the isolation of the house where the stove is installed.
The information is indicative and could be subject to variations without notice
back